ARCODE Lift Command Panels
> Connection with cabinet units
Serial cabin communication via CANbus line Between control panel and revision box
One-to-one connection with plug-in flat cable Plug-in between cabin button and inspection box
one-cable plug-in connection
> Connection with floor units
Serial floor communication via CANbus line or parallel floor connection with MSP16 card.
Additive, well CANbus line with plug-in cables from floor to floor, extending throughout the entire well
Pluggable connection with plug-in cable attached to the well CANbus line for each floor for floor buttons
> Compact inspection panel on cabinet
Easy to use mobile device with 2 meters long hand terminal device
> Door contacts connection
Door contact installation with plug-in cables extending from floor to floor, extending all along the shaft
Connection with socket cables attached to the door contact system on each floor for the plug-lock contacts of the landing doors.
> Pit installation
Socket connection via a single cable with the bottom of the pit box and mobile and easy use with the hand terminal
> Cab position information
With encoder system With magnetic switch and magnets
> Cable coding
Fast fault resolution thanks to the cable labeled with colors and texts
> Automatic door control
All kinds of automatic door control Independent door control according to the stops with double door support
1 door control inputs-outputs in the inspection box and 2 in the control panel
> Auto floor
With 1 phase 220VAC UPS or battery group connection Easy direction or to the desired floor
> Door bridging
Door early opening and door open level renewal with door bridging circuit on DBR card
>Programmable I/O
Freely programmable inputs and outputs on the motherboard, cabin cards and floor cards
> Test functions
Special test function for testing car and landing button connections
> Remote control
Ability to control ARCODE from any point with the hand terminal connected to the CANbus line
> Cabin-well feeding circuits
Residual current protected cabin and well supply fuses
> Emergency alarm
Emergency alarm siren (with buttons from the top of the cabin and the bottom of the well)
> Safety circuit connections
Special connections for safety circuits in control panel, inspection box and pit box
> Eligibility
Full compliance with EN 81-20 standards as a complete elevator control system with EMC test report
Infinity Lift Ascensores prioritizes customer satisfaction in all its services. In order to meet all the needs and expectations of its customers, it tries to understand their wishes fully and completely. According to Infinity Lift Ascensores, quality and service beyond expectations should always be given to every customer in the best way possible.
Your satisfaction cannot be exchanged for anything for us.