Arkel Apre is a Clamping Control Unit for EN81-1 + A3 Standards. With the addition of the Connection Card Battery, it continues to work in the event of a mains interruption. Battery charging is done by ApRe card.
peed Regulator Locking Coil Voltage
12 Vdc or 24 Vdc. Supply and battery connection is sufficient according to the coil voltage.
Maximum Coil Current
6A
Normal Supply
For 12Vdc Coil: 11-14 Vdc For 24Vdc Coil: 20-27 Vdc
Battery Supply
For 12Vdc Coil: 12 Vdc/ 1.2 Ah For 24Vdc Coil: 24 Vdc/1.2 Ah
Internal Battery Charge
With Direct Current Source
Security Circuit Entry
190-230 Vac
Average Power Consumption
When the coil is unpowered and the battery is full: < 1W When the coil is unpowered and the battery is full: < 10W
Dimensions (mm)
120 x 100 x 46 (Width x Length x Height)
Weight (gr)
Without box: 300 With Box: 330
Compliance to Standards
EN 81-1+A3
Infinity Lift Ascensores prioritizes customer satisfaction in all its services. In order to meet all the needs and expectations of its customers, it tries to understand their wishes fully and completely. According to Infinity Lift Ascensores, quality and service beyond expectations should always be given to every customer in the best way possible.